IVES GD-611

An electrical stimulator base unit whose treatment and setting functions are condensed in a compact body.

A Variety of Treatment Modes for a Wide Range of Pathologies

IVES™ has a total of six treatment modes: Power Assist mode, which is the core mode, along with External Assist, Trigger, External Trigger, Normal, and Sensor Trigger modes. A single stimulator allows the therapist to support a variety of patient conditions and carry out rehabilitation aimed at reducing muscular atrophy and pain.

Save Treatment Settings for Up to 45 Patients

IVES™ can store treatment settings for up to 45 patients. Names can be assigned for easy recall, eliminating the need to manually enter the settings during every visit.

GD-612 Programming Functionality and Usage History

Connect the base unit GD-611 to the sub-unit GD-612 to export a patient’s treatment settings for patient use. The patient’s GD-612 usage history, including total usage time, number of times stimulation was emitted, and total duration, can later be viewed with GD-611.

Product name Electrical Stimulator GD-611
Rated power supply 6 VDC (Four AA batteries)
Power input 1.9 VA
External dimensions Approx. 85 × 145 × 35(H) mm
Weight Approx. 300 g (including batteries)
Maximum output voltage 210 Vp-p (at a 500 Ω load)
Maximum output current 35 mArms (Frequency: 100 Hz, load resistance: 500 Ω)
Pulse width Three repetitive outputs of 50 μsec each
Output frequency 20 Hz: Power Assist Mode, External Assist Mode. 1 to 100 Hz: Normal Mode, Trigger Mode, External Trigger Mode, Sensor Trigger Mode
Treatment mode Normal Mode / Trigger Mode / Power Assist Mode / Sensor Trigger Mode (when Gait Sensor is being used) / External Trigger Mode (when using 2-pole Electrode Cord) / External Power Assist Mode (when using 2-pole Electrode Cord)
Treatment time Normal Mode, Trigger Mode, Power Assist Mode, External Trigger Mode, External Assist Mode: 5, 10, 15, 20, 25, 30 minutes and continuous. Sensor Trigger Mode: continuous only
Safety function Over-current protection function, zero-start output safety feature, operation lock function, low battery alarm function, final voltage detection function

Made in Japan