Product Information

Gore VIABAHN VBX Balloon Expandable Endoprosthesis

Gore Medical Endovascular & Vascular Surgery Devices Available for Quote

Need this product?

Request a quote from AMMT for availability, pricing, technical specifications, compatibility, or project requirements.

Product Details

Description & Specifications

Review the full product information, specifications, images, videos, and supporting details below.

```html

Gore VIABAHN® VBX Balloon Expandable Endoprosthesis

The Gore VIABAHN® VBX Balloon Expandable Endoprosthesis, also known as the VBX Stent Graft, is designed for challenging vascular procedures where flexibility, strength, placement accuracy, and long-term durability are essential. Engineered to support precise deployment and reliable vessel treatment, the VBX Stent Graft combines a balloon-expandable platform with the benefits of a covered stent graft design.

Built with independent stainless steel rings and a heparin-bonded surface, the VIABAHN® VBX Endoprosthesis is designed to provide high radial strength, vessel conformability, controlled expansion, and minimized foreshortening. Its broad range of diameters, lengths, catheter configurations, and adjustability makes it suitable for a wide range of vascular anatomy and clinical requirements.

Clinical Applications

The VIABAHN® VBX Balloon Expandable Endoprosthesis is used in vascular interventions where a covered balloon-expandable stent graft is required for accurate placement, strong vessel support, and durable performance.

Vascular Intervention

  • Balloon-expandable covered stent graft procedures
  • Complex vascular anatomy support
  • Procedures requiring accurate stent graft placement
  • Vessel reinforcement and endovascular treatment

Challenging Vascular Conditions

  • Procedures requiring high radial strength
  • Cases requiring vessel conformability
  • Applications requiring minimized foreshortening
  • Interventions requiring diameter adjustability

Advanced Technology and Design

Broad Diameter and Length Offering

The VBX Stent Graft is available in a wide selection of diameters and lengths, supporting different vessel sizes and procedural needs.

Diameter Adjustability

Designed with broad diameter adjustability in a single device, helping clinicians adapt to patient anatomy and procedural requirements.

6 Fr-Compatible Configurations

Multiple configurations are compatible with 6 Fr access, supporting procedural flexibility and access planning.

Independent Stainless Steel Rings

Independent stainless steel ring design enhances flexibility, conformability, and radial strength across available sizes.

Minimized Foreshortening

The design helps minimize foreshortening during deployment, supporting accurate placement and controlled positioning.

Heparin-Bonded Device Options

Available configurations include heparin-bonded options to support vascular performance during endovascular procedures.

Key Features

  • Balloon-expandable covered stent graft design
  • Engineered for challenging vascular conditions
  • Independent stainless steel ring construction
  • High radial strength across available sizes
  • Flexible and conformable vessel support
  • Minimized foreshortening for controlled placement
  • Broad diameter adjustability in selected configurations
  • Available in multiple diameters, lengths, and catheter configurations

Available Sizes and Configurations

Gore VIABAHN® VBX Balloon Expandable Endoprosthesis is available in multiple diameters, lengths, catheter sizes, and heparin-bonded configurations.

Item Number Description
BXA051502E VIABAHN BX Balloon Expandable Endoprosthesis | 5 mm × 15 mm | 7 Fr | 135 cm Catheter | Heparin
BXA051902E VIABAHN BX Balloon Expandable Endoprosthesis | 5 mm × 19 mm | 7 Fr | 135 cm Catheter | Heparin
BXA052902E VIABAHN BX Balloon Expandable Endoprosthesis | 5 mm × 29 mm | 7 Fr | 135 cm Catheter | Heparin
BXA053902E VIABAHN BX Balloon Expandable Endoprosthesis | 5 mm × 39 mm | 7 Fr | 135 cm Catheter | Heparin
BXA055902E VIABAHN BX Balloon Expandable Endoprosthesis | 5 mm × 59 mm | 7 Fr | 135 cm Catheter | Heparin
BXA057902E VIABAHN BX Balloon Expandable Endoprosthesis | 5 mm × 79 mm | 7 Fr | 135 cm Catheter | Heparin
BXA061502E VIABAHN BX Balloon Expandable Endoprosthesis | 6 mm × 15 mm | 7 Fr | 135 cm Catheter | Heparin
BXA061902E VIABAHN BX Balloon Expandable Endoprosthesis | 6 mm × 19 mm | 7 Fr | 135 cm Catheter | Heparin
BXA062902E VIABAHN BX Balloon Expandable Endoprosthesis | 6 mm × 29 mm | 7 Fr | 135 cm Catheter | Heparin
BXA063902E VIABAHN BX Balloon Expandable Endoprosthesis | 6 mm × 39 mm | 7 Fr | 135 cm Catheter | Heparin
BXA065902E VIABAHN BX Balloon Expandable Endoprosthesis | 6 mm × 59 mm | 7 Fr | 135 cm Catheter | Heparin
BXA067902E VIABAHN BX Balloon Expandable Endoprosthesis | 6 mm × 79 mm | 7 Fr | 135 cm Catheter | Heparin
BXA071502E VIABAHN BX Balloon Expandable Endoprosthesis | 7 mm × 15 mm | 7 Fr | 135 cm Catheter | Heparin
BXA071902E VIABAHN BX Balloon Expandable Endoprosthesis | 7 mm × 19 mm | 7 Fr | 135 cm Catheter | Heparin
BXA072902E VIABAHN BX Balloon Expandable Endoprosthesis | 7 mm × 29 mm | 7 Fr | 135 cm Catheter | Heparin
BXA073902E VIABAHN BX Balloon Expandable Endoprosthesis | 7 mm × 39 mm | 7 Fr | 135 cm Catheter | Heparin
BXA075902E VIABAHN BX Balloon Expandable Endoprosthesis | 7 mm × 59 mm | 7 Fr | 135 cm Catheter | Heparin
BXA077902E VIABAHN BX Balloon Expandable Endoprosthesis | 7 mm × 79 mm | 7 Fr | 135 cm Catheter | Heparin
BXA082902E VIABAHN BX Balloon Expandable Endoprosthesis | 8 mm × 29 mm | 7 Fr | 135 cm Catheter | Heparin
BXA083902E VIABAHN BX Balloon Expandable Endoprosthesis | 8 mm × 39 mm | 7 Fr | 135 cm Catheter | Heparin
BXA085902E VIABAHN BX Balloon Expandable Endoprosthesis | 8 mm × 59 mm | 7 Fr | 135 cm Catheter | Heparin
BXA087902E VIABAHN BX Balloon Expandable Endoprosthesis | 8 mm × 79 mm | 8 Fr | 135 cm Catheter | Heparin
BXA092902E VIABAHN BX Balloon Expandable Endoprosthesis | 9 mm × 29 mm | 8 Fr | 135 cm Catheter | Heparin
BXA093902E VIABAHN BX Balloon Expandable Endoprosthesis | 9 mm × 39 mm | 8 Fr | 135 cm Catheter | Heparin
BXA095902E VIABAHN BX Balloon Expandable Endoprosthesis | 9 mm × 59 mm | 8 Fr | 135 cm Catheter | Heparin
BXA097902E VIABAHN BX Balloon Expandable Endoprosthesis | 9 mm × 79 mm | 8 Fr | 135 cm Catheter | Heparin
BXA102902E VIABAHN BX Balloon Expandable Endoprosthesis | 10 mm × 29 mm | 8 Fr | 135 cm Catheter | Heparin
BXA103902E VIABAHN BX Balloon Expandable Endoprosthesis | 10 mm × 39 mm | 8 Fr | 135 cm Catheter | Heparin
BXA105902E VIABAHN BX Balloon Expandable Endoprosthesis | 10 mm × 59 mm | 8 Fr | 135 cm Catheter | Heparin
BXA107902E VIABAHN BX Balloon Expandable Endoprosthesis | 10 mm × 79 mm | 8 Fr | 135 cm Catheter | Heparin
BXA112902E VIABAHN BX Balloon Expandable Endoprosthesis | 11 mm × 29 mm | 8 Fr | 135 cm Catheter | Heparin
BXA113902E VIABAHN BX Balloon Expandable Endoprosthesis | 11 mm × 39 mm | 8 Fr | 135 cm Catheter | Heparin
BXA115902E VIABAHN BX Balloon Expandable Endoprosthesis | 11 mm × 59 mm | 8 Fr | 135 cm Catheter | Heparin
BXA117902E VIABAHN BX Balloon Expandable Endoprosthesis | 11 mm × 79 mm | 8 Fr | 135 cm Catheter | Heparin
BXAL082902E VIABAHN BX Balloon Expandable Endoprosthesis | 8 mm × 29 mm | 7 Fr | 135 cm Catheter | Heparin | Long
BXAL083902E VIABAHN BX Balloon Expandable Endoprosthesis | 8 mm × 39 mm | 7 Fr | 135 cm Catheter | Heparin | Long
BXAL085902E VIABAHN BX Balloon Expandable Endoprosthesis | 8 mm × 59 mm | 7 Fr | 135 cm Catheter | Heparin | Long
BXAL087902E VIABAHN BX Balloon Expandable Endoprosthesis | 8 mm × 79 mm | 8 Fr | 135 cm Catheter | Heparin | Long

Balloon Expandable Stent Graft for Challenging Vascular Procedures

The Gore VIABAHN® VBX Balloon Expandable Endoprosthesis provides a covered balloon-expandable stent graft solution for vascular procedures requiring strength, flexibility, vessel conformability, and precise placement. With independent stainless steel ring construction, minimized foreshortening, broad diameter adjustability, multiple catheter configurations, and heparin-bonded options, the VBX Stent Graft is designed to support reliable performance in demanding endovascular applications.

```
Need assistance?

Speak to AMMT About Gore VIABAHN VBX Balloon Expandable Endoprosthesis

Our team can support with product availability, quotations, procurement support, technical clarification, and project requirements.

Request Quote