Gore VIABAHN® VBX Balloon Expandable Endoprosthesis – Reduced Profile
The Gore VIABAHN® VBX Balloon Expandable Endoprosthesis – Reduced Profile is designed to deliver trusted stent graft performance with enhanced versatility across a broad range of peripheral vascular indications. With a 1 Fr profile reduction on the majority of sizes, the reduced-profile VBX Stent Graft provides expanded 6 Fr compatibility for more procedural flexibility.
Engineered for challenging vascular anatomy, the reduced-profile VBX Stent Graft combines flexibility, radial strength, vessel conformability, controlled deployment, and diameter customization. Its independent stainless steel ring design helps minimize foreshortening and supports precise placement, while the covered semi-compliant balloon improves device retention and tracking through tortuous anatomy and tight angles.
Built on more than 20 years of Gore peripheral stent graft experience, the device leverages proven VIABAHN® Endoprosthesis technology and features Gore’s CBAS® Heparin Surface for lasting thromboresistance.
Key Highlights
Reduced Profile
1 Fr profile reduction on the majority of sizes supports greater access flexibility and more 6 Fr-compatible configurations.
Lengths up to 79 mm
Available in lengths up to 79 mm, supporting treatment of a broader range of vascular lesions and procedural requirements.
Diameter Adjustability
Designed with broad diameter adjustability in a single device for greater customization during treatment.
Clinical Applications
The reduced-profile VIABAHN® VBX Balloon Expandable Endoprosthesis is used in peripheral vascular interventions where a covered balloon-expandable stent graft is required for flexibility, strength, placement accuracy, and long-term performance.
Peripheral Vascular Intervention
- Peripheral vascular indications
- Balloon-expandable covered stent graft procedures
- Complex vascular anatomy support
- Cases requiring precise deployment
Challenging Anatomy
- Tortuous anatomy and tight angles
- Procedures requiring high radial strength
- Cases requiring vessel conformability
- Applications requiring reduced-profile access
Advanced Technology and Design
Broad Diameter and Length Offering
The reduced-profile VBX Stent Graft is available in multiple diameters and lengths, including lengths up to 79 mm.
6 Fr Compatibility
A reduced device profile provides more 6 Fr-compatible configurations, supporting greater versatility across more cases.
Independent Stainless Steel Rings
Stainless steel independent ring construction enhances flexibility, vessel conformability, and radial strength.
Minimized Foreshortening
The device design helps minimize foreshortening for more precise deployment and controlled placement.
Covered Semi-Compliant Balloon
Covered semi-compliant balloon design improves device retention on the catheter while tracking through tortuous anatomy and tight angles.
CBAS® Heparin Surface
Features Gore’s CBAS® Heparin Surface, designed to support lasting thromboresistance.
Key Features
- Reduced-profile balloon-expandable covered stent graft design
- 1 Fr profile reduction on the majority of sizes
- More 6 Fr-compatible configurations
- Lengths available up to 79 mm
- Broad diameter adjustability in a single device
- Independent stainless steel ring construction
- Designed to enhance flexibility and vessel conformability
- Designed to minimize foreshortening for precise deployment
- High radial strength
- Covered semi-compliant balloon for retention and tracking performance
- Diameter customization after deployment
- CBAS® Heparin Surface for lasting thromboresistance
Available Sizes and Configurations
Gore VIABAHN® VBX Balloon Expandable Endoprosthesis – Reduced Profile is available in multiple diameters, lengths, sheath sizes, catheter configurations, and heparin-bonded options.
| Item Number | Diameter | Length | Sheath | Catheter | Surface |
|---|---|---|---|---|---|
| BXB051502E | 5 mm | 15 mm | 6 Fr | 135 cm | Heparin |
| BXB051902E | 5 mm | 19 mm | 6 Fr | 135 cm | Heparin |
| BXB052902E | 5 mm | 29 mm | 6 Fr | 135 cm | Heparin |
| BXB053902E | 5 mm | 39 mm | 6 Fr | 135 cm | Heparin |
| BXB055902E | 5 mm | 59 mm | 6 Fr | 135 cm | Heparin |
| BXB057902E | 5 mm | 79 mm | 6 Fr | 135 cm | Heparin |
| BXB061502E | 6 mm | 15 mm | 6 Fr | 135 cm | Heparin |
| BXB061902E | 6 mm | 19 mm | 6 Fr | 135 cm | Heparin |
| BXB062902E | 6 mm | 29 mm | 6 Fr | 135 cm | Heparin |
| BXB063902E | 6 mm | 39 mm | 6 Fr | 135 cm | Heparin |
| BXB065902E | 6 mm | 59 mm | 6 Fr | 135 cm | Heparin |
| BXB067902E | 6 mm | 79 mm | 6 Fr | 135 cm | Heparin |
| BXB071502E | 7 mm | 15 mm | 6 Fr | 135 cm | Heparin |
| BXB071902E | 7 mm | 19 mm | 6 Fr | 135 cm | Heparin |
| BXB072902E | 7 mm | 29 mm | 6 Fr | 135 cm | Heparin |
| BXB073902E | 7 mm | 39 mm | 6 Fr | 135 cm | Heparin |
| BXB075902E | 7 mm | 59 mm | 6 Fr | 135 cm | Heparin |
| BXB077902E | 7 mm | 79 mm | 6 Fr | 135 cm | Heparin |
| BXB082902E | 8 mm | 29 mm | 7 Fr | 135 cm | Heparin |
| BXB083902E | 8 mm | 39 mm | 7 Fr | 135 cm | Heparin |
| BXB085902E | 8 mm | 59 mm | 7 Fr | 135 cm | Heparin |
| BXB087902E | 8 mm | 79 mm | 7 Fr | 135 cm | Heparin |
| BXB092902E | 9 mm | 29 mm | 7 Fr | 135 cm | Heparin |
| BXB093902E | 9 mm | 39 mm | 7 Fr | 135 cm | Heparin |
| BXB095902E | 9 mm | 59 mm | 7 Fr | 135 cm | Heparin |
| BXB097902E | 9 mm | 79 mm | 7 Fr | 135 cm | Heparin |
| BXBL082902E | 8 mm | 29 mm | 7 Fr | 135 cm | Heparin (Long) |
| BXBL083902E | 8 mm | 39 mm | 7 Fr | 135 cm | Heparin (Long) |
| BXBL085902E | 8 mm | 59 mm | 8 Fr | 135 cm | Heparin (Long) |
| BXBL087902E | 8 mm | 79 mm | 8 Fr | 135 cm | Heparin (Long) |
Reduced-Profile Balloon Expandable Stent Graft for Peripheral Vascular Procedures
The Gore VIABAHN® VBX Balloon Expandable Endoprosthesis – Reduced Profile provides a lower-profile covered stent graft solution for peripheral vascular procedures requiring flexibility, high radial strength, vessel conformability, and placement accuracy. With expanded 6 Fr compatibility, lengths up to 79 mm, independent stainless steel rings, covered semi-compliant balloon technology, diameter customization, and CBAS® Heparin Surface, the reduced-profile VBX Stent Graft supports versatile performance across challenging vascular cases.